Super-efficient Rooftop Unit with Inverter Compressor & EC motor

Product Overview


—— Product Description ——


Withair® packaged rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, "no-strip screw" collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally (R-410A) refrigerant and are factory tested. Withair® packaged rooftop unit applicability is wide and used in shopping malls, hotels, factories, villas, commercial housing, office buildings, shops, hospitals and other places.



—— The Key Advantages Include ——


●  All model sizes share a common, compact cabinet in a single footprint for on-site flexibility.

●  Installation time and costs are reduced by easy power and control wiring. All units are factory-wired, charged and tested prior to shipment.

●  Delivers clean, dehumidified outside air in all weather and climate conditions.

●  Compressor is internally protected against high pressure and temperature.

●  Units are engineered and built to be among the quietest models.

●  Up to 100% outside air.

●  Convertible airflow design means no panel cutting is required, and no accessory panel is necessary.

●  Heat exchangers are corrosion-resistant, with aluminized steel tubular construction for durability and long service life.

●  Post-purge induced draft combustion exhausts combustion products from the heat exchanger to prolong heat exchanger life.

●  Secured service access ports are protected, externally mounted and reusable on both high and low lines.

●  Complete line of field-installed accessories, including propane and high altitude conversion kits, economizers, single- and dual-enthalpy sensors and more.

●  Evaporator coils are constructed with grooved copper tubes and enhanced for construction to improve heat transfer.

●  Condenser coils are constructed of MicroChannel aluminum tubing and aluminum fins for durability and long-lasting efficient operation.

●  Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement.

●  Access panels with easy grip handles and tool-less filter access door

●  Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application

●  Low Maintenance- No condensation occurs at the zone-level terminal units, meaning no drain pans to clean and no condensate drain traps and piping to install and maintain. And, since the cooling coil in each terminal unit operates dry, an optional upstream filter is available, but not required.


—— Product Features ——


The unique structure design of the oval tube improves the heat exchanger efficiency by 42% and reduces the air resistance by 34%


a) High efficiency--Heat transfer efficiency increased by 42%

b) Low pressure loss--Air resistance reduced by 34%

c) Low refrigerant usage--40% reduction in refrigerant usage, making the equipment more efficient and less CO2 emission




  







1. Multi-compressors system - provide up to 4 grades of refrigeration capacity regulation, optional variable capacity digital scroll compressor can further improve the equipment energy saving and control accuracy.

2. Double layer board gold structure -- polyamine foam double layer board gold structure pioneered by yilong.The highest thermal resistance in the industry is 2.8m2℃/w.

3. Electronic expansion valve - provides the most accurate superheat control (1℃) while reducing equipment failure rate.

4. Controller - optional PLC programmable controller improves field control adaptability and makes network connection faster.

5. Heat exchanger - the world's first oval tube heat exchanger to greatly improve the energy saving level.

6. Reheater (optional) - reheat is provided through waste heat of condenser without electric heating.

7. Heat recovery wheel (optional) - there are two options, sensible heat and total heat, to absorb the energy in the exhaust air.

8. Enthalpy difference controller (optional) - when the outdoor enthalpy value is lower than the indoor enthalpy value, the compressor is closed and the outdoor natural air is utilized cooling room environment.

9. Secondary air return (side) - humidity control through secondary air return is the most energy-saving humidity control solution.

10. Gas heating (optional) - gas heating can be used in winter to provide stable heating.

11. High efficiency fan motor - straight connected vortex free case backward tilt fan greatly improves fan efficiency.

12. Types selection - air - cooled type or water - cooled type for option.


Air volume and compressor capacity automatically matching

Withair's Rooftop Unit can provide up to 7 levels of air volume regulation, greatly improving the energy efficiency of the equipment.For example, when indoor load is low, only one compressor is working, at this time, the air supply volume will be automatically reduced to 15-20% of the total air volume to achieve the energy saving goal.

When the indoor load increases, for example, two compressors are needed to put into operation, the air supply will automatically increase to match the cooling capacity.



—— The Directions of Air Supply & Air Inlet ——


Multiple optional air supply methods, so that Withair Rooftop air conditioner can adapt to a variety of building conditions.

Whether indoor or outdoor, whether the roof or the ground, it can be a good design layout.


—— Rapid Product Customization Services ——


Customer's personalized demand for Rooftop Unit  is the design concept of Withair. our each Rooftop Unit can be customized according

to the customer's special requirements.Our engineers will quickly design each personalized roof machine, including the structure, function

and control can be customized.



Physical Data


Super-efficient Inverter Rooftop Unit (1)

Model  W05R1-
14RFA 18RFA 22RFA 28RFA 33RFA 40RFA 45RFA 50RFA 56RFA 61RFA
Rated cooling capacity kW 14.0 18.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5
Ton 4.0 5.1 6.4 8.0 9.5 11.4 12.8 14.2 15.9 17.5
Rated cooling input power kW 3.46 4.40 5.05 7.00 8.70 10.70 12.70 14.30 16.50 18.60
Rated EER W/W 4.05 4.09 4.44 4.00 3.85 3.74 3.54 3.50 3.39 3.31
Rated heating capacity kW 16.0 21.0 26.0 32.0 38.5 46.0 52.0 58.0 65.0 71.0
Ton 4.5 6.0 7.4 9.1 10.9 13.1 14.8 16.5 18.5 20.2
Rated heating input power kW 2.9 4.0 5.3 7.2 8.8 10.9 12.4 14.0 16.5 18.7
Rated COP W/W 5.5 5.3 4.9 4.5 4.4 4.2 4.2 4.1 3.9 3.8
Air supply m3/h 1950~2600 2700~3600 3360~4480 4200~5600 5025~6700 6000~8000 6750~9000 7500~10000 8400~11200 9225~12300
External static pressure Pa 200 200 220 220 250 250 250 250 250 270
Condensate pipe Inch 1 1 1 1 1 1 1 1 1 1
Capacity control
Continuous
Temperature control
Microcomputer thermostat
Compressor
DC Inverter Hermetic high efficiency scroll compressor
Refrigerant 
R410A
Power supply
380-415V/3P/50Hz   (380V/460V/3P/60Hz and 208V/1(3)Ph/60Hz as an option)
Protection devices
High pressure protector,low pressure protector,compressor overheating protection,fusible plug,reverse-phase protection, exhaust overheat   protection, compressor overcurrent protection, fan overcurrent protection,etc
Filter
Dismountable and compliant with the ASHEAE52-76 standards, dust intercept rate >95%
Heat exchanger type
High efficiency finned copper pipe heat exchanger
Gas-fuel  heater 
Optional parts,  standard units are not configured
Air exhauster
Optional parts,  standard units are not configured
Economizer
Optional parts,  standard units are not configured
Heat recovery
Optional parts,  standard units are not configured
Noise level dB(A) 48 50 52 53 55 56 56 58 58 60
Dimension Length mm 1,295 1,295 1,615 1,615 1,615 2,070 2,070 2,070 2,070 2,070
Width mm 765 765 765 765 765 765 765 765 765 765
Height mm 1,680 1,680 1,680 1,680 1,680 1,680 1,680 1,680 1,680 1,680
Weight Net kg 275 320 380 450 520 560 630 760 851 990
Gross kg 320 370 440 520 600 650 730 880 980 1,250

Notes: 

1. Cooling condition: indoor air inlet dry bulb temperature 27℃, wet bulb temperature 19℃, outdoor air inlet dry bulb temperature 35℃. 

2. Heating condition: indoor air inlet dry bulb temperature 20℃, outdoor air inlet dry bulb temperature 7℃, wet bulb temperature 6℃.

3. Constant temperature and humidity type,  100% fresh air and partial fresh air, heat recovery and cooling only model are for your option. 

4. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications.


Super-efficient Inverter Rooftop Unit (2)

Model  W05R1-
67RFA 80RFA 100RFA 112RFA 123RFA 160RFA 182RFA 198RFA 246RFA 270RFA
Rated cooling capacity kW 67.0 80.0 100.0 112.0 123.0 160.0 182.0 198.0 246.0 270.0
Ton 19.1 22.7 28.4 31.8 35.0 45.5 51.7 56.3 69.9 76.8
Rated cooling input power kW 17.40 21.40 28.60 33.00 37.20 42.80 50.80 57.20 69.60 74.40
Rated EER W/W 3.85 3.74 3.50 3.39 3.31 3.74 3.58 3.46 3.53 3.63
Rated heating capacity kW 77.0 92.0 115.0 129.0 142.0 184.0 210.0 228.0 283.0 311.0
Ton 21.9 26.2 32.7 36.7 40.4 52.3 59.7 64.8 80.5 88.4
Rated heating input power kW 17.6 21.8 28.0 33.0 37.4 43.6 49.6 56.0 70.5 74.8
Rated COP W/W 4.4 4.2 4.1 3.9 3.8 4.2 4.2 4.1 4.0 4.2
Air supply m3/h 10050~13400 12000~16000 15000~2000 16800~22400 18450~24600 24000~32000 27300~36400 29700~39600 36900~49200 40500~54000
External static pressure Pa 300 300 300 320 320 350 350 400 400 450
Condensate pipe Inch 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 2 2 2
Capacity control
Continuous
Temperature control
Microcomputer thermostat
Compressor
DC Inverter Hermetic high efficiency scroll compressor
Refrigerant 
R410A
Power supply
380-415V/3P/50Hz   (380V/460V/3P/60Hz and 208V/1(3)Ph/60Hz as an option)
Protection devices

High pressure protector,low pressure protector,compressor overheating protection,fusible plug,reverse-phase protection, exhaust overheat

protection, compressor overcurrent protection, fan overcurrent protection, etc

Filter
Dismountable and compliant with the ASHEAE52-76 standards, dust intercept rate >95%
Heat exchanger type
High efficiency finned copper pipe heat exchanger
Gas-fuel heater 
Optional parts,  standard units are not configured
Air exhauster
Optional parts,  standard units are not configured
Economizer
Optional parts,  standard units are not configured
Heat recovery
Optional parts,  standard units are not configured
Noise level dB(A) 61 62 62 64 64 65 66 67 68 68
Dimension Length mm 2,230 2,540 2,540 2,840 2,840 4,110 4,110 4,740 4,740 6,300
Width mm 1,980 1,980 1,980 1,980 1,980 1,980 1,980 1,980 1,980 1,980
Height mm 1,680 1,680 1,680 1,900 1,900 2,400 2,400 2,400 2,400 2,400
Weight Net kg 1,050 1,120 1,160 1,290 1,420 1,650 1,950 2,260 2,470 2,810
Gross kg 1,180 1,320 1,390 1,510 1,650 1,920 2,160 2,520 2,790 3,270

Notes: 

1. Cooling condition: indoor air inlet dry bulb temperature 27℃, wet bulb temperature 19℃, outdoor air inlet dry bulb temperature 35℃. 

2. Heating condition: indoor air inlet dry bulb temperature 20℃, outdoor air inlet dry bulb temperature 7℃, wet bulb temperature 6℃.

3. Constant temperature and humidity type,  100% fresh air and partial fresh air, heat recovery and cooling only model are for your option. 

4. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications.


Super-efficient Inverter Rooftop Unit (3)

Model  W05R1-
338RFA 370RFA 450RFA 505RFA 550RFA 600RFA 670RFA 740RFA 790RFA 840RFA
Rated cooling capacity kW 338.0 370.0 450.0 505.0 550.0 600.0 670.0 740.0 790.0 840.0
Ton 96.1 105.2 127.9 143.6 156.4 170.6 190.5 210.4 224.6 238.8
Rated cooling input power kW 85.60 101.60 124.00 139.90 152.40 166.70 186.70 207.30 222.00 236.60
Rated EER W/W 3.95 3.64 3.63 3.61 3.61 3.60 3.59 3.57 3.56 3.55
Rated heating capacity kW 387.0 426.0 518.0 581.0 633.0 690.0 771.0 851.0 909.0 966.0
Ton 110.0 121.1 147.3 165.2 180.0 196.2 219.2 242.0 258.5 274.7
Rated heating input power kW 87.2 99.2 121.3 136.4 149.0 163.2 182.7 202.6 217.0 231.7
Rated COP W/W 4.4 4.3 4.3 4.3 4.2 4.2 4.2 4.2 4.2 4.2
Air supply m3/h 50400~67200 55500~74000 67500~90000 75750~101000 82500~110000 90000~120000 100500~134000 11100~148000 118500~158000 126000~168000
External static pressure Pa 450 450 480 480 500 500 550 550 600 600
Condensate pipe Inch 2 2 2 2 2 2 2 2 2 2
Capacity control
Continuous
Temperature control
Microcomputer thermostat
Compressor
DC Inverter Hermetic high efficiency scroll compressor
Refrigerant 
R410A
Power supply
380-415V/3P/50Hz   (380V/460V/3P/60Hz and 208V/1(3)Ph/60Hz as an option)
Protection devices

High pressure protector,low pressure protector,compressor overheating protection,fusible plug,reverse-phase protection, exhaust overheat

protection, compressor overcurrent protection, fan overcurrent protection, etc

Filter
Dismountable and compliant with the ASHEAE52-76 standards, dust intercept rate >95%
Heat exchanger type
High efficiency finned copper pipe heat exchanger
Gass-fuel heater 
Optional parts,  standard units are not configured
Air exhauster
Optional parts,  standard units are not configured
Economizer
Optional parts,  standard units are not configured
Heat recovery
Optional parts,  standard units are not configured
Noise level dB(A) 69 69 70 71 72 72 74 75 76 78
Dimension Length mm 6,700 7,000 7,730 7,730 7,730 10,300 10,300 10,300 111,000 111,000
Width mm 1,980 1,980 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600
Height mm 2,400 2,400 2,800 2,800 2,800 2,800 2,800 2,800 2,800 2,800
Weight Net kg 3,200 3,500 4,790 5,000 5,200 6,260 6,600 7,000 8,000 9,000
Gross kg 3,500 3,850 5,200 5,500 5,860 6,950 7,450 7,820 8,960 10,500

Notes: 

1. Cooling condition: indoor air inlet dry bulb temperature 27℃, wet bulb temperature 19℃, outdoor air inlet dry bulb temperature 35℃. 

2. Heating condition: indoor air inlet dry bulb temperature 20℃, outdoor air inlet dry bulb temperature 7℃, wet bulb temperature 6℃.

3. Constant temperature and humidity type,  100% fresh air and partial fresh air, heat recovery and cooling only model are for your option. 

4. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications.


Packaging & Transportation

- 

● Four steps of pakacges, plastic film, foam, carton and plywood for stable transporation.

● 100% test before deliverying products.
● Item shipped in 25 working days against payment depends on the quantity.
● Products catalogue, installation & operation manual will be sent together.
● Tracking number will be sent to customer as soon as we ship the products.
● Ocean shipping, railway shipment and air transportation are acceptable according to customer demand.


Withair® provides two styles package for different transporation modes:

(1). St andard package(free of charge): unit is wrapped with plastic film, foam and carton, which is suitable for container shipment & a few transshipment cargo;
                 
(2). Special pac kage(extra charge): unit is wrapped with plastic film and wooded box, which is suitable for bulk cargo transporation; 
       


Catalogue Download



                       Withair®_ Packaged Rooftop Unit Catalogue 2017.pdf






Get Best Quote

Through Wall Packaged Heat Pump

Up To 100% Fresh Air DC Inverter Rooftop Unit

Full DC Inverter Ductable Split Air conditioner

Inverter Heat Pump Water Heater

Inverter Air Cooled Heat Pump